Products & Services Solutions Academia Support User Community Company

Learn more about RF Toolbox   

Function Reference


CalculationsCalculate parameters of circuit objects, model objects, and networks
Data VisualizationDisplay circuit object parameters
UtilitiesCalculate intermediate results
Network Parameter ConversionConvert network parameters between formats
GUIOpen the RF Analysis Tool

Calculations

cascadesparamsCascade S-parameters to form cascaded network
deembedsparamsDe-embed 2-port S-parameters
gamma2zConvert reflection coefficient to impedance
gammainCalculate input reflection coefficient of 2-port network
gammamlCalculate load reflection coefficient of 2-port network for simultaneous conjugate match
gammamsCalculate source reflection coefficient of 2-port network required for simultaneous conjugate match
ispassiveCheck passivity of N-port S-parameters
makepassiveEnforce passivity of S-parameters
powergainCalculate power gain of 2-port network
rationalfitFit rational function to broadband data
s2tfConvert S-parameters of 2-port network to voltage or power-wave transfer function
stabilitykCalculate stability factor K of 2-port network
stabilitymuCalculate stability factor μ of 2-port network
vswrCalculate VSWR at given reflection coefficient Γ
z2gammaConvert impedance to reflection coefficient

Data Visualization

smithchartPlot complex vector on Smith chart

Utilities

copyCopy circuit or data object
getdataData object containing analyzed result of specified circuit object

Network Parameter Conversion

abcd2hConvert ABCD-parameters to hybrid h-parameters
abcd2sConvert ABCD-parameters to S-parameters
abcd2yConvert ABCD-parameters to Y-parameters
h2abcdConvert hybrid h-parameters to ABCD-parameters
h2gConvert hybrid h-parameters to hybrid g-parameters
h2sConvert hybrid h-parameters to S-parameters
h2yConvert hybrid h-parameters to Y-parameters
h2zConvert hybrid h-parameters to Z-parameters
s2abcdConvert S-parameters to ABCD-parameters
s2hConvert S-parameters to hybrid h-parameters
s2sConvert S-parameters to S-parameters with different impedance
s2sccConvert 4-port, single-ended S-parameters to 2-port, common-mode S-parameters (Scc)
s2scdConvert 4-port, single-ended S-parameters to 2-port, cross-mode S-parameters (Scd)
s2sdcConvert 4-port, single-ended S-parameters to 2-port, cross-mode S-parameters (Sdc)
s2sddConvert 4-port, single-ended S-parameters to 2-port, differential-mode S-parameters (Sdd)
s2smmConvert single-ended 4N-port S-parameters to mixed-mode 2N-port S-parameters
s2tConvert S-parameters to T-parameters
s2yConvert S-parameters to Y-parameters
s2zConvert S-parameters to Z-parameters
smm2sConvert mixed-mode 2N-port S-parameters to single-ended 4N-port S-parameters
snp2smpConvert single-ended N-port S-parameters to single-ended M-port S-parameters
t2sConvert T-parameters to S-parameters
y2abcdConvert Y-parameters to ABCD-parameters
y2hConvert Y-parameters to hybrid h-parameters
y2sConvert Y-parameters to S-parameters
y2zConvert Y-parameters to Z-parameters
z2abcdConvert Z-parameters to ABCD-parameters
z2hConvert Z-parameters to hybrid h-parameters
z2sConvert Z-parameters to S-parameters
z2yConvert Z-parameters to Y-parameters

GUI

rftoolOpen RF Analysis Tool (RF Tool)
  


Recommended Products

Includes the most popular MATLAB recorded presentations with Q&A sessions led by MATLAB experts.

 © 1984-2010- The MathWorks, Inc.    -   Site Help   -   Patents   -   Trademarks   -   Privacy Policy   -   Preventing Piracy   -   RSS